<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15357</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 1 distance out of range
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error should not occur during normal machine operation. If it does,
first try selecting the RESUME button from the workstation dialog box.  If
that doesn't correct the problem, then select RESET TRENDSETTER from
the workstation TRENDSETTER pull-down menu. If the problem persists,
call Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Re-issue the command with a correct distance.
</text></DescriptionText>
</ServiceInformation>
<Cause>
This error occurs if a "vr move" or "vr jog" command is issued from the
diagnostic monitor with a distance parameter that exceeds the maximum stepper
travel limit specified by the "aldrv 1" limit parameter. This error should
not occur during normal machine operation.  Report it to the product TTE.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/aldrv_cfg_limit.xml</LinkAddress><LinkTitle>NVS: aldrv limit</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:04 2008 PST
</Updated>
<Links>
</Links>
</Error>